ACOUSTIC
IGU’s

ACOUSTIC GLASS

Noise Reduction

Acoustic laminated is a high-quality laminated glass with a PVB (polyvinylbutyral) acoustic interlayer that considerably reduces noise. It is designed to reflect and absorb the soundwaves and limit sound frequencies moving between the panes of glass, significantly reducing noise intrusion.

Acoustic laminates have a significantly improved performance compared with standard laminated glass of the same composition using conventional PVB.

Acoustic glass is used to improve sound reduction and control environmental noise from the ground and air traffic, school playgrounds, and various other sources such as factories or bars.

The desired acoustic performance can be achieved by combining various thicknesses of glass with
a special PVB interlayer. With a large variety of product combinations, acoustic glass offers the opportunity to achieve specific noise reduction requirements.

ACOUSTIC
GLAZED UNITS

Rw is the weighted sound reduction, in decibels, which incorporates a correction for the ears. C and Ctr are the spectrum adjustments, which are the values added to Rw to consider the characteristics of the sound spectra.

An acoustic IGU offers all the benefits of laminated glass; safety, security, and UV protection without compromising on light transmittance, providing you with all the comfort and security you need at home. Glazing and windows play an important part in reducing unwanted noise.

Acoustic glass can be combined with other products to create a multifunctional product such as solar control, thermal insulation and self-cleaning.

Structure and

coefficients

Standard acoustic insulation coefficients
on the basis of

EN 12758 and EN 12354-3
Structure [mm] Acoustic insulation coefficient
at average frequencies [Hz]

R [dB]

Acoustic insulation coefficient and adaptive coefficients

[dB]

125 250 500 1k 2k 4k Rw Ctr C
This chart presents standard values of the weighted acoustic insulation coefficient Rw, as well as the coefficient R for different frequencies of sounds tested for the essential structures of double glazed glass units presented in glass trade magazines and technical publications. Single glass
3 14 19 25 29 33 25 28 -4 -1
4 17 20 26 32 33 26 29 -3 -2
5 19 22 29 33 29 31 30 -2 -1
6 18 23 30 35 27 32 31 -3 -2
8 20 24 29 34 29 37 32 -3 -2
10 23 26 32 31 32 39 33 -3 -2
12 27 29 31 32 38 47 34 -2 0
Laminated glass

Rw– weighted acoustic insulation coefficient

Ctrcorrective coefficient for sound sources containing a large number of low frequencies, for example urban road traffic

C – corrective coefficient for sound sources containing few low frequencies for example high speed road traffic, high speed rail traffic, children playing

6,4 (VSG.33.1) 20 23 29 34 32 38 32 -3 -1
8,8 (VSG 44.2) 20 25 32 35 34 42 33 -3 -1
9,5 (VSG 44.4) 24 26 33 33 35 44 34 -3 -1
Double glazing
4/(6-16)/4 21 17 25 35 37 31 29 -4 -1
6/(6-16)/4 21 20 26 38 37 39 32 -4 -2
6/(6-16)/6 20 18 28 38 34 38 31 -4 -1
8/(6-16)/6 20 21 33 40 36 48 35 -6 -2
10/(6-16)/4 24 21 32 37 42 43 35 -5 -2
10/(6-16)/6 24 24 32 37 37 44 35 -3 -1
6,4 (VSG 33.1)/(6-16)/6 20 19 30 39 37 46 33 -5 -2
6,4 (VSG 33.1)/(6-16)/10 24 25 33 39 40 49 37 -5 -1
Structure [mm] Type of used gas
Acoustic
insulation coefficient
Rw [dB]
C
[dB]
Ctr
[dB]
RA RAtr Acoustic insulation coefficient
at average [Hz] R [dB]
T-Thermofloat 125 250 500 1k 2k 4k
12 Float 35 -1 -3 34 32 29 30 35 31 39 49
12,8 (VSG 66.2) 37 -1 -3 36 34 30 31 35 34 41 51
15 Float 37 -1 -3 36 34 33 32 34 32 44 52
16,8 (VSG 88.2) 39 -1 -3 38 36 33 34 35 35 46 56
12,8 (VSG 66.2) Acoustic 40 -1 -3 39 37 28 32 37 41 41 50
16,8 (VSG 88.2) Acoustic 42 0 -3 42 39 31 35 39 41 46 54
Structure [mm] Type of used gas
Acoustic
insulation coefficient
Rw [dB]
C
[dB]
Ctr
[dB]
RA RAtr Acoustic insulation coefficient
at average [Hz] R [dB]
T-Thermofloat 125 250 500 1k 2k 4k
4/16/4T Argon 31 -2 -5 29 26 25 16 27 41 46 43
6/12/6T Argon 33 -1 -4 32 29 23 19 32 40 30 43
6,4 (VSG 33.1)/16/4T Argon 34 -1 -5 33 29 21 22 31 45 44 48
6/16/4T Argon 34 -1 -5 33 29 26 24 31 45 39 44
8T/16/8 Argon 34 -1 -4 33 30 21 26 33 39 34 46
6/16/6,4T (VSG 33.1T) Argon 35 -3 -7 32 28 22 18 34 43 38 51
6,4 (VSG 33.1)/12/6,4T (VSG 33.1T) Argon 35 -2 -6 33 29 22 20 32 43 41 55
8/16/4T Argon 36 -2 -6 34 30 26 24 34 43 44 46
8/18/4T Argon 36 -1 -5 35 31 24 25 34 43 45 48
8/20/5T Argon 36 -1 -5 35 31 23 25 33 43 40 50
10/16/4T Argon 37 -3 -7 34 30 27 26 35 40 48 50
8/16/6,8T (VSG 33.2T) Argon 37 -2 -6 35 31 18 24 38 44 40 56
8/20/4T Argon 37 -2 -6 35 31 24 26 34 43 45 47
8/16/8,8T (VSG 44.2T) Argon 37 -2 -5 35 32 26 25 36 43 40 54
8,8 (VSG 44.2)/16/4T Argon 37 -1 -5 36 32 28 26 35 44 47 51
8,4 (VSG 44.1)/16/6T Argon 38 -3 -7 35 31 26 28 38 46 38 51
8,8 (VSG 44.2)/12/8,8T (VSG 44.2T) Argon 38 -2 -6 36 32 24 26 36 44 44 61
8/14/6T Argon 38 -1 -5 37 33 22 28 39 44 38 51
10/12/6T Argon 38 -1 -4 37 34 28 27 36 38 40 48
8,8 (VSG 44.2)/16/6T Argon 39 -2 -6 37 34 27 28 38 46 42 56
8,8 (VSG 44.2)/20/6T Argon 39 -2 -5 37 34 24 29 40 45 38 54
8T/16/10 Argon 39 -2 -5 37 34 24 31 39 41 38 51
8,4 (VSG 44.1) Acoustic/16/4T Argon 39 -1 -5 38 34 27 26 36 49 53 55
6,4 (VSG 33.1) Acoustic/16/6T Argon 40 -2 -6 38 34 25 26 37 49 47 58
6/12/8,4T (VSG 44.1T) Acoustic Argon 40 -2 -6 38 34 29 27 37 48 47 56
8,8 (VSG 44.2)/16/6,4T (VSG 33.1T) Argon 40 -2 -6 38 34 26 26 39 47 42 56
9,5 (VSG 44.4)/16/6T Argon 40 -2 -6 38 34 27 32 39 45 41 54
12,8 (VSG 66.2)/12/6T Argon 40 -1 -5 39 35 27 30 37 43 43 57
6,4 (VSG 33.1) Acoustic/12/6,4T (VSG 33.1T) Acoustic Argon 40 -1 -5 39 35 29 27 37 51 59 59
6/16/10,8T (VSG 55.2T) Argon 40 -1 -4 39 36 25 31 36 43 41 53
8/20/8,8T (VSG 44.2T) Argon 40 -1 -4 39 36 27 31 40 44 42 54
8T/16/12 Argon 40 -1 -3 39 37 25 34 40 39 40 52
8,4 (VSG 44.1) Acoustic/16/6T Argon 41 -2 -6 39 35 23 28 40 49 46 59
8,8 (VSG 44.2) Acoustic/16/6,8T (VSG 33.2T) Argon 41 -2 -6 39 35 21 30 42 48 48 56
8/12/8,4T (VSG 44.1T) Acoustic Argon 41 -2 -6 39 35 29 28 38 48 49 60
13,5 (VSG 66.4)/16/8T Argon 41 -1 -5 40 36 31 33 40 42 46 62
6/20/10,8T (VSG 55.2T) Argon 41 -1 -5 40 36 24 34 39 44 42 50
10/16/12,8T (VSG 66.2T) Argon 41 -1 -4 40 37 28 34 41 38 45 58
13,5 (VSG 66.4)/16/12T Argon 41 -1 -4 40 37 32 34 40 38 50 65
8/16/10,8T (VSG 55.2T) Argon 41 -1 -4 40 37 27 31 42 43 41 54
8T/16/10,8 (VSG 55.2) Acoustic Argon 42 -3 -8 39 34 20 32 42 47 46 55
6/16/10,8T (VSG 55.2T) Acoustic Argon 42 -3 -7 39 34 26 29 42 50 47 58
8,8 (VSG 44.2) Acoustic/16/6T Argon 42 -3 -7 39 35 26 30 40 50 47 54
12,8 (VSG 66.2) Acoustic/12/8T Argon 42 -2 -6 40 36 25 32 41 44 45 57
8,8 (VSG 44.2) Acoustic/20/6T Argon 42 -2 -6 40 36 23 30 42 49 44 56
8/16/8,8T (VSG 44.2T) Acoustic Argon 42 -2 -6 40 36 24 29 40 49 49 59
8/20/10,8 (VSG 55.2) Argon 42 -2 -5 40 37 25 33 40 43 42 58
10/24/8,8T (VSG 44.2T) Argon 42 -1 -4 41 38 30 35 42 42 44 61
9,5 (VSG 44.4)/16/12,8T (VSG 66.2T) Argon 43 -2 -7 41 36 25 35 43 44 46 62
12,8 (VSG 66.2)/12/8,8T (VSG 44.2T) Argon 43 -2 -6 41 37 26 32 42 47 48 59
6/20/10,8T (VSG 55.2T) Acoustic Argon 43 -2 -6 41 37 25 34 43 50 45 58
8,8 (VSG 44.2) Acoustic/12/8,8T (VSG 44.2T) Argon 43 -2 -6 41 37 26 32 42 51 54 61
10/14/16,8T (VSG 88.2T) Argon 43 -2 -4 41 39 29 38 42 38 45 56
12,8 (VSG 66.2) Acoustic/12/10T Argon 43 -1 -5 42 38 28 36 43 43 47 57
8/16/10,8T (VSG 55.2T) Acoustic Argon 44 -3 -7 41 37 27 32 43 49 47 58
8/20/8,4T (VSG 44.1T) Acoustic Argon 44 -2 -6 42 38 29 31 43 49 50 57
16,8 (VSG 88.2) Acoustic/12/10T Argon 44 -1 -4 43 40 30 39 44 42 48 57
8,8T (VSG 44.2T) Acoustic/16/8,8T (VSG 44.2T) Acoustic Argon 45 -3 -8 42 37 21 34 46 52 54 57
10,8 (VSG 55.2) Acoustic/12/8,8T (VSG 44.2T) Acoustic Argon 45 -2 -7 43 38 30 33 43 53 57 67
10/16/8,8T (VSG 44.2T) Acoustic Argon 45 -2 -6 43 39 27 36 44 47 52 60
10/16/12,8T (VSG 66.2T) Acoustic Argon 45 -1 -4 44 41 33 36 44 46 48 57
9,5 (VSG 44.4)/20/8,8T (VSG 44.2T) Acoustic Argon 46 -3 -7 43 39 29 36 43 50 52 60
10/20/8,8T (VSG 44.2T) Acoustic Argon 46 -1 -5 45 41 27 35 44 48 54 60
10/20/10,8T (VSG 55.2T) Acoustic Argon 46 -1 -4 45 42 33 37 44 47 49 57
12,8 (VSG 66.2) Acoustic/16/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -7 45 40 26 39 46 51 54 61
11,5 (VSG 55.4)/20/13,5 (VSG 66.4) Argon 47 -1 -4 46 43 38 39 46 46 51 68
13,5T (VSG 66.4T) Acoustic/14/12,8T (VSG 66.2T) Acoustic Argon 48 -2 -6 46 42 28 39 48 51 52 60
16,8 (VSG 88.2) Acoustic/16/12,8T (VSG 66.2T) Acoustic Argon 50 -1 -4 49 46 37 39 47 51 53 61
12,8 (VSG 66.2) Acoustic/20/8,8T (VSG 44.2T) Acoustic Argon 51 -2 -7 49 44 30 41 48 56 55 62
15,5 (VSG 68.4) Acoustic/15/16,8T (VSG 88.2T) Acoustic Argon 51 -1 -4 50 47 39 40 47 51 55 62
16,8 (VSG 88.2) Acoustic/20/12,8T (VSG 66.2T) Acoustic Argon 51 -1 -3 50 47 41 45 49 49 56 71
Structure [mm] Type of used gas
Acoustic
insulation coefficient
Rw [dB]
C
[dB]
Ctr
[dB]
RA RAtr Acoustic insulation coefficient
at average [Hz] R [dB]
T-Thermofloat 125 250 500 1k 2k 4k
4T/10 Termo/4/10 Termo/4T Argon 31 -1 -5 30 26 24 19 27 42 50 46
4T/12/4/12/4T Argon 33 -2 -5 31 28 17 23 29 43 51 44
6T/12/3/12/4T Argon 35 -2 -7 33 28 20 24 31 45 45 47
6T/12/6/12/6T Argon 35 -2 -7 33 28 14 25 34 45 40 56
4T/12/4/12/6,4T (VSG 33.1T) Argon 35 -1 -6 34 29 16 25 32 47 50 55
8,8T (VSG 44.2T)/12/4/12/4T Argon 36 -2 -7 34 29 20 24 36 47 51 54
6,4T (VSG 33.1T)/12/6/12/4T Argon 36 -2 -6 34 30 21 25 32 46 46 53
6T/12/4/12/4T Argon 36 -2 -6 34 30 18 26 32 47 48 48
6T/12/5/12/4T Argon 36 -2 -6 34 30 20 24 32 46 45 49
6,4T (VSG 33.1T)/12/4/12/6,4T (VSG 33.1T) Argon 37 -3 -8 34 29 12 27 35 47 43 59
6,4T (VSG 33.1T) Acoustic/12/6/12/4T Argon 37 -2 -6 35 31 18 25 35 50 56 57
8T/12/6/12/6T Argon 37 -2 -6 35 31 16 25 39 46 36 56
8T/12/4/12/6T Argon 38 -1 -5 37 33 21 29 37 43 40 56
8,8T (VSG 44.2T)/12/4/12/8,8T (VSG 44.2T) Argon 39 -3 -8 36 31 19 29 39 47 48 64
8T/12/8/12/6,8T (VSG 33.2T) Argon 39 -3 -8 36 31 15 27 38 48 44 63
8,8T (VSG 44.2T)/12/4/12/6,4T (VSG 33.1T) Argon 39 -2 -8 37 31 17 28 39 49 44 62
10/12/6/12/4 Argon 39 -2 -7 37 32 18 29 36 42 48 54
8,8T (VSG 44.2T)/12/6/12/8,8T (VSG 44.2T) Argon 40 -3 -8 37 32 20 30 39 47 46 63
6T/14/4/14/ 9,5T (VSG 44.4T) Argon 40 -2 -8 38 32 17 32 40 49 43 60
6T/12/6/12/8,8T (VSG 44.2T) Argon 40 -2 -7 38 33 20 29 39 47 43 57
9,5T (44.4T)/12/6/12/6T Argon 40 -2 -7 38 33 19 28 40 50 42 59
6T/12/4/12/8,8T (VSG 44.2T) Argon 41 -3 -8 38 33 16 33 41 51 51 60
6T/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 41 -3 -8 38 33 17 31 41 51 49 59
10T/14/4/14/6T Argon 41 -1 -6 40 35 22 36 40 43 41 55
8,8T (VSG 44.2T) Acoustic/12/6/12/4T Argon 41 -1 -5 40 36 22 29 40 50 52 52
8T/14/4/14/8,4T (VSG 44.1T) Argon 41 -1 -5 40 36 29 30 39 46 43 55
8T/12/4/12/10,8T (VSG 55.2T) Argon 42 -2 -6 40 36 21 33 42 44 44 63
6T/12/4/12/8,8T (VSG 44.2T) Acoustic Argon 42 -1 -6 41 36 23 33 39 51 50 60
8T/12/6/12/8,8T (VSG 44.2T) Argon 43 -3 -8 40 35 19 33 44 48 49 56
6T/12/6/12/10,8T (VSG 55.2T) Argon 43 -2 -7 41 36 21 33 43 51 48 57
8T/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 43 -2 -7 41 36 23 31 42 50 51 65
6,4T (VSG 33.1T) Acoustic/12/4/12/6,4T (VSG 33.1T) Acoustic Argon 43 -2 -6 41 37 25 30 40 53 57 61
8T/12/6/12/10,8T (VSG 55.2T) Argon 43 -2 -6 41 37 24 34 41 46 47 60
8/16/6/16/10,8 (VSG 55.2) Argon 43 -2 -5 41 38 26 33 42 43 44 53
12,8T (VSG 66.2T)/12/6/12/6T Argon 43 -1 -6 42 37 27 34 41 47 45 61
8,8T (VSG 44.2T) Acoustic/12/6/10/10 Argon 44 -3 -8 41 36 24 34 43 49 52 64
8T/12/8/12/10,8T (VSG 55.2T) Argon 44 -3 -7 41 37 21 33 45 50 48 57
8T/12/6/12/10,8T (VSG 55.2T) Acoustic Argon 44 -2 -7 42 37 23 32 43 49 47 65
12,8T (VSG 66.2T)/16/4/16/6T Argon 44 -2 -6 42 38 30 38 42 46 46 56
8T/14/4/14/8,8T (VSG 44.1T) Acoustic Argon 44 -1 -5 43 39 29 31 40 49 49 58
10,8T (VSG 55.2T) Acoustic/16/6/16/8T Argon 45 -2 -7 43 38 27 33 44 51 51 67
9,5T (VSG 44.4T)/14/4/14/9,5T (VSG 44.4T) Acoustic Argon 45 -2 -7 43 38 27 35 45 52 51 65
8/16/6/16/10,8 (VSG 55.2) Acoustic Argon 45 -2 -5 43 40 28 33 45 49 46 55
8T/16/6/16/12,8T (VSG 66.2T) Argon 45 -1 -5 44 40 29 38 45 43 48 58
10T/12/6/12/12,8T (VSG 66.2T) Acoustic Argon 46 -2 -6 44 40 28 38 45 46 49 67
6,4T (VSG 33.1T)/12/4/12/26,6 Pyrobel 25 Argon 46 -2 -6 44 40 35 39 44 48 55 59
8T/16/6/16/12,8T (VSG 66.2T) Acoustic Argon 46 -2 -6 44 40 25 36 45 49 50 60
9,5T (VSG 44.4T)/18/4/15/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -8 45 39 26 37 48 53 53 56
8,4T (VSG 44.1T) Acoustic/12/4/12/8,4T (VSG 44.1T) Acoustic Argon 47 -2 -6 45 41 28 34 44 53 57 61
8,4T (VSG 44.1T) Acoustic/12/6/12/8,4T (VSG 44.1T) Acoustic Argon 47 -2 -6 45 41 28 34 45 53 56 61
8,8T (VSG 44.2T) Acoustic/12/6/12/8,4T (VSG 44.1T) Acoustic Argon 47 -2 -6 45 41 28 34 45 52 56 62
8,8T (VSG 44.2T) Acoustic/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -6 45 41 28 33 46 53 56 61
9,5T (VSG 44.4T)/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -6 45 41 28 35 44 52 55 61
9,5T (VSG 44.4T)/12/8/12/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -6 45 41 29 34 46 52 55 60
10/16/6/16/10,8 (VSG 55.2) Acoustic Argon 47 -2 -5 45 42 30 37 45 48 48 56
13,5T (VSG 66.4T) Acoustic/14/4/14/9,5T (VSG 44.4T) Argon 47 -1 -5 46 42 31 37 47 51 48 56
12,8T (VSG 66.2T)/16/4/16/9,5T (VSG 44.4T) Argon 47 -1 -4 46 43 32 39 46 47 49 61
8,8T (VSG 44.2T) Acoustic/12/6/12/12,8T (VSG 66.2T) Acoustic Argon 48 -3 -8 45 40 24 40 47 53 55 60
8,8T (VSG 44.2T) Acoustic/12/8/12/8,4T (VSG 44.1T) Acoustic Argon 48 -2 -7 45 41 26 35 47 53 57 61
8,8T (VSG 44.2T) Acoustic/12/8/12/8,8T (VSG 44.2T) Acoustic Argon 48 -2 -7 46 41 28 35 47 54 57 61
10,8T (VSG 55.2T) Acoustic/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 48 -2 -6 46 42 29 35 46 54 56 62
13,5T (VSG 66.4T) Acoustic/14/4/12/11,5T (VSG 55.4T) Argon 48 -1 -4 47 44 33 40 48 49 49 56
12,8T (VSG 66.2T)/16/4/16/27,8T P8B Argon 48 -1 -3 47 45 32 39 46 47 49 61
12,8T (VSG 66.2T)/16/4/18/23T P7B Argon 49 -2 -4 47 45 39 44 48 43 54 63
15,5T (VSG 68.4T) Acoustic/12/4/12/15T (VSG 66.8T) Acoustic Argon 50 -1 -3 50 47 37 43 49 50 53 59
13,5T (VSG 66.4T) Acoustic/14/8/12/13,5T (VSG 66.4T) Acoustic Argon 51 -1 -4 50 47 37 43 51 52 53 61
15,5 (VSG 68.4) Acoustic/15/4/12/16,8T (VSG 88.2T) Acoustic Argon 52 -1 -3 51 49 42 43 51 52 55 70

Additionally, Glass Systems offers a wide range of alternative specifications available from the PRESS GLASS group.

ACOUSTIC
GLAZED UNITS

SOUNDPROOF

GLASS CONFIGURATOR

Easy to use configuration tool:

  • select acoustic IGU by acoustic parameters
  • save configurations to PDF

NOISE

SIMULATOR

An intuitive-to-use simulator enables:

  • simulation of noise reduction for acoustic IGUs
  • a selection of six types of noise
  • comparison of auditory effects between all acoustic IGUs,
  • limiting a comparison to single glass, double or triple IGUs,
;